Feed water parameters
Maximum TDS 2,000 ppm
Iron, maximum 0.3 ppm
Hardness (less than) 15 gpg
Hydrogen Sulfide Zero
Manganese (less than) 0.05 ppm
Turbidity (less than) 1 NTU
Pressure, minimum without pump 30 psi
Pressure, maximum 100 psi
pH 3 - 11
Note: Pretreatment suggested if conditions exceed parameters.
Models
FMRO5-M-PT 50 GPD membrane with plastic tank
FMRO5-M-MT 50 GPD membrane with metal tan
k
Warranty
Systems are assembled in Phoenix, Arizona, and
come with a one year limited warranty. (Please
see warranty card for more details.)
Specifications
Production, FMRO5-M-PT 50 GPD
Production, FMRO5-M-MT 50 GPD
Storage tank capacity 2.6 gals.
Faucet Lead-free*
Membrane Thin Film
NSF Certification Std. 58
* Meets State of California’s lead-free requirements.
Maintenance
Recommended membrane and cartridge
replacement:
Membrane:
Change based on periodic TDS rejection tests,
or change is typically necessary every 2-3 years.
Pre and post filters:
Change every six months under heavy usage or
every year with light usage.
© 2004 Flowmatic Systems, Inc. Printed in U.S.A.
Flowmatic
®
NSF certified manifold RO systems reduce these drinking water contaminants
■
Chlorine
■
Copper
■
Radium 226 / 228
■
Tastes & odors*
■
Cadmium
■
Lead
■
Chromium (Trivalent)
■
Perchlorate
■
Giardia Cysts
■
Arsenic
■
Barium
■
Turbidity
■
Entamoeba
■
Cryptosporidium
■
Fluoride
■
Toxoplasma
■
Selenium
■
Chromium (Hexavalent)
■
TDS
■
Nitrate / Nitrite
*Tested and verified by independent laboratory testing.
Authorized dealer
Available from authorized dealers
Flowmatic
®
reverse osmosis drinking water systems are available from authorized dealers. For sales, installation
and service please contact the dealer listed below: