Watts M1115-2 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour l'eau Watts M1115-2. Watts M1115-2 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
12541 Gulf Freeway Houston, Texas 77034 (Ph) 713.943.0688 (Fx) 713.944.9445 www.watts.com
X – Isolation Cocks
FC – Flo-Clean Strainer
Y – Y-Strainer (Replaces Flo-Clean)
ACS Adjustable Closing Speed
(Replaces Fixed Orice)
AOS Adjustable Opening Speed
P – Position Indicator
L – Limit Switch
05/09
Mustang series
Standard Components
Options & Accessories
(3)
(3)
(3)
(2)
(2)
(1)
(1)
Standard 3” & Smaller
Standard 4” & Larger
Optional All Sizes
(3)
(2)
(1)
Schematic
910 link
1
X
X
X
Y/FC
P/L
3
4
2
CLOSES VALVE
OPENS VALVE
FLOW
(AOS)
M115-2 (Globe)
M1115-2 (Angle)
Operations
PRESSURE REDUCING CONTROL VALVE
WITH PRESSURE SUSTAINING FEATURE
Throttles to reduce high upstream pressure to constant
lower downstream pressure
Throttles to maintain minimum upstream pressure
Reducing and Sustaining setpoints are separately
adjustable
1 – Main Valve (Single Chamber)
2 – Pressure Reducing Control
3 – Pressure Sustaining Control
4 – Fixed Orice
The Combination Pressure Reducing and Pressure Sustaining Control Valve is designed to automatically
reduce a uctuating higher upstream pressure to a constant lower downstream pressure regardless of
varying ow rates, and will throttle to sustain a minimum upstream pressure. It is controlled by a normally
open, pressure reducing pilot designed to: 1) Open (allowing uid out of the main valve cover chamber)
when downstream pressure is below the adjustable setpoint, and 2) Close (allowing uid to ll the main valve
cover chamber) when downstream pressure is above the adjustable setpoint. A decrease in downstream
pressure causes the valve to modulate toward an open position, raising downstream pressure. An increase
in downstream pressure causes the valve to modulate toward a closed position, lowering downstream
pressure.
The normally closed sustaining pilot remains open when upstream pressure is above the adjustable setpoint,
and modulates toward a closed position if upstream pressure falls below the setpoint. As the sustaining pilot
closes, uid is directed into the main valve cover chamber, allowing the valve to modulate toward a closed
position, raising upstream pressure. Normal pressure reducing operation resumes when upstream pressure
is above the sustaining pilot setpoint, and downstream pressure is below the reducing pilot setpoint.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Mustang series

12541 Gulf Freeway • Houston, Texas 77034 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.watts.com ○ X – Isolation Cocks ○ FC –

Page 2

12541 Gulf Freeway • Houston, Texas 77034 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.watts.comMustang seriesOperating Pressure Ope

Page 3

12541 Gulf Freeway • Houston, Texas 77034 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.watts.comMustang seriesSizingCAVITATION ZONEI

Page 4

12541 Gulf Freeway • Houston, Texas 77034 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.watts.comMustang series910 Ops & Inst Cro

Page 5

12541 Gulf Freeway • Houston, Texas 77034 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.watts.comMustang seriesModel CP-15Pressure Re

Page 6

12541 Gulf Freeway • Houston, Texas 77034 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.watts.comMustang seriesControls and Accessori

Page 7

12541 Gulf Freeway • Houston, Texas 77034 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.watts.comMustang seriesM115-2 (Globe)M1115-2

Page 8

12541 Gulf Freeway • Houston, Texas 77034 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.watts.comMustang seriesSpecicationsM115-2 (G

Modèles reliés M115-2