Watts PWRO4ZRO Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour l'eau Watts PWRO4ZRO. Watts PWRO4ZRO User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Installation, Operation
and Maintenance Manual
Zero Waste Reverse Osmosis System
Model PWRO4ZRO
IOM-WQ-PWRO4ZRO
Table of Contents Pages
Operational Parameters...................................3
Contents of Reverse Osmosis System........................3
Tools Recommended For Installation .........................3
Drill a Hole for the Faucet in a Porcelain Sink ...................3
Punch a Hole for the Faucet in a Stainless Steel Sink.............3
How to use Quick-Connect Fittings ..........................4
Watts Top Mount Faucet Installation .........................5
Adapt-A-Valve™ Installation ...............................5
Reverse Osmosis Module Mounting .........................5
Green Tube Connection...................................6
Black Tube Connection ...................................6
Check Air Pressure in the Tank .............................6
Tank Ball Valve Installation .................................6
Final Filter Installation.....................................6
Start up Instructions .....................................7
6-Month Maintenance ....................................8
Annual Maintenance .....................................8
Membrane Replacement ..................................9
Procedure for Extended Non-Use (More than 2 months) ..........9
Troubleshooting........................................10
Parts List .............................................11
Arsenic Facts..........................................12
Service Record ........................................13
Limited Warranty .......................................16
PWRO4ZRO
PURE WATER
System tested and certified by NSF International
against NSF/ANSI Standard 58 for the reduction
of the claims specified on the performance data
sheet.
Note: Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Important
Please read the entire manual before proceeding with the
installation and startup. Your failure to follow any attached
instructions or operating parameters may lead to the product’s
failure.
Save manual for future reference.
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - PURE WATER

Installation, Operation and Maintenance ManualZero Waste Reverse Osmosis SystemModel PWRO4ZROIOM-WQ-PWRO4ZROTable of Contents PagesOperational Param

Page 2 - Introduction

10PROBLEM CAUSE SOLUTION1. Low/slow production Excessive air pressure in tank Relieve pressure at schrader valve on tank (set to 7psi with the tank e

Page 3 - ***IMPORTANT NOTICE***

11 Parts ListCOLD-WATERSHUT-OFF VALVECARBONPRE-FILTERSEDIMENTPRE-FILTERTEEFITTINGMEMBRANE HOUSINGSTORAGE TANK1/4” GREEN TUBEFEED WATERCARBONPOST-FILTE

Page 4

12 Arsenic FactsArsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must b

Page 5 - 2" Configuration

13DATE OF PURCHASE DATE OF INSTALL INSTALLED BYDATE 1ST STAGE SEDIMENT (6 MONTHS)2ND STAGE CARBON (6 MONTHS)3RD STAGE CARBON (6 MONTHS)FINAL FILTER

Page 8 - Annual Maintenance

IOM-WQ-PWRO4ZRO 1225 EDP# 2915899 © 2012 WattsUSA: Tel. (800) 224-1299 • www.watts.com Canada: Tel. (888) 208-8927 • www.watts.caA Watts Water T

Page 9 - Membrane Replacement

2IntroductionThank you for your purchase of a state of the art Watts Reverse Osmosis (RO) water treatment system. Water quality concerns are becoming

Page 10 - Troubleshooting

3Operating Temperatures Maximum 100°F (37.8°C) Minimum 40°F (4.4°C)Operating PressureMaximum 85psi (6.0 kg/cm2)Minimum 40psi (2.80 kg/cm2)pH Paramet

Page 11 - Parts List

4How to use the Quick-Connect fittings on the RO ModuleTo make a connection, the tube is simply pushed into the fitting. Place a piece of tape 1/2"

Page 12 - Arsenic Facts

5STEP 4Reverse Osmosis Module MountingStep A – Determine best location for the RO module to be mounted to allow for future system main-tenance. The p

Page 13 - Service Record

6STEP 5Green Tube ConnectionStep A – Locate green tube attached to the RO Module. Insert the open end of the green 1⁄4" tube into the open 1⁄4&q

Page 14

7 Start Up Instructions Warning: To prevent the possibility of electrical shock, clean up any water on cabinet floor and dry all water from outside of

Page 15

8Step E – Clean the filter housings (bowls) with a mild soap solution and rinse with water. Check O-rings and lubricate with water soluble lubricant.

Page 16

9 Membrane Replacement This reverse osmosis system contains a replaceable component (the RO membrane) which is critical to the efficiency of the system