Watts PWROKCZRO Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour l'eau Watts PWROKCZRO. Watts PWROKCZRO User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Installation, Operation
and Maintenance Manual
Kwik-Change™ Zero Waste Reverse Osmosis
Model PWROKCZRO
IOM-WQ-PWROKCZRO
Important
Please read the entire manual before proceeding with the
installation and startup Your failure to follow any attached
instructions or operating parameters may lead to the product’s
failure.
Save manual for future reference.
Table of Contents
Operational Parameters...................................3
Contents of Reverse Osmosis System........................3
Tools Recommended For Installation .........................3
Drill a Hole for the Faucet in a Porcelain Sink ...................3
How To Use Quick-Connect Fittings For Tubing Connections ......4
Punch a Hole for the Faucet in a Stainless Steel Sink.............3
Faucet Installation .......................................5
Installation of Hot and Cold water supply valves ................5
Reverse Osmosis Module Mounting .........................5
Connect the Tubing to the Hot and Cold Water Valves............5
Tank Ball Valve Installation .................................6
Check Air Pressure in the Tank .............................6
Blue Tube Connection (From RO Module To The Tank) ...........6
Blue Tube Connection (From RO Module to the Faucet)...........6
Start up Instructions .....................................6
6-Month System Maintenance..............................7
Annual System Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Membrane Replacement .................................8
Parts List / Unit Drawing ..................................9
Troubleshooting .......................................10
Arsenic Fact Sheet .....................................11
Limited Warranty .......................................12
PWROKCZRO
PURE WATER
Note: Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after
the system.
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - PURE WATER

Installation, Operation and Maintenance ManualKwik-Change™ Zero Waste Reverse OsmosisModel PWROKCZROIOM-WQ-PWROKCZROImportantPlease read the entire m

Page 2 - Introduction

10probleM cause solution1. Low/Slow Production Low Water Pressure Assure a minimum of 40psi incoming water pressure. Watts sells a booster pump if hom

Page 3 - ***IMPORTANT NOTICE***

11 Arsenic FactsArsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must b

Page 4

IOM-WQ-PWROKCZRO 1225 EDP# 2915873 © 2012 WattsUSA: Tel. (800) 224-1299 • www.watts.com Canada: Tel. (888) 208-8927 • www.watts.caA Watts Water

Page 5 - 2" Configuration

2IntroductionThank you for your purchase of a state of the art Watts Kwik-Change™ Zero Waste Reverse Osmosis (RO) water treatment system. Water qualit

Page 6

3Operating Temperatures Maximum 100°F (37.8°C) Minimum 40°F (4.4°C)Operating PressureMaximum 85psi (6.0 kg/cm2)Minimum 40psi (2.80 kg/cm2)pH Paramet

Page 7 - Annual Maintenance

4How To Use the Quick-Connect Fittings For Tubing ConnectionsTo make a connection, the tube is simply pushed into the fitting. Place a piece of tape 1

Page 8 - Membrane Replacement

5STEP 4Reverse Osmosis Module MountingStep A – Determine best location for the RO module to be mounted to allow for future system main-tenance. The p

Page 9 - Parts List

6Step A – Teflon tape must be applied in a clockwise direction. Wrap (4 to 8 turns) around the male pipe threads (MPT) on the stainless steel fitting o

Page 10 - Troubleshooting

7Order filter by calling Watts at 1-800-224-1299Item Needed: EDP# 7100109Includes: • (1) Carbon Block FilterThis reverse osmosis system contains a rep

Page 11 - Arsenic Facts

8 Membrane Replacement This reverse osmosis system contains a replaceable component (the RO membrane) which is critical to the efficiency of the system

Page 12

9iteM # edp # description1 7300052 MODULE2 7300034 ELBOW - 1/4" QC X 1/4" STEM (NOT SHOWN)3 7300025 FLOW RESTRICTOR (NOT SHOWN)4 7300000 TR