Installation, Operation and Maintenance ManualKwik-Change™ Zero Waste Reverse OsmosisModel PWROKCZROIOM-WQ-PWROKCZROImportantPlease read the entire m
10probleM cause solution1. Low/Slow Production Low Water Pressure Assure a minimum of 40psi incoming water pressure. Watts sells a booster pump if hom
11 Arsenic FactsArsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must b
IOM-WQ-PWROKCZRO 1225 EDP# 2915873 © 2012 WattsUSA: Tel. (800) 224-1299 • www.watts.com Canada: Tel. (888) 208-8927 • www.watts.caA Watts Water
2IntroductionThank you for your purchase of a state of the art Watts Kwik-Change™ Zero Waste Reverse Osmosis (RO) water treatment system. Water qualit
3Operating Temperatures Maximum 100°F (37.8°C) Minimum 40°F (4.4°C)Operating PressureMaximum 85psi (6.0 kg/cm2)Minimum 40psi (2.80 kg/cm2)pH Paramet
4How To Use the Quick-Connect Fittings For Tubing ConnectionsTo make a connection, the tube is simply pushed into the fitting. Place a piece of tape 1
5STEP 4Reverse Osmosis Module MountingStep A – Determine best location for the RO module to be mounted to allow for future system main-tenance. The p
6Step A – Teflon tape must be applied in a clockwise direction. Wrap (4 to 8 turns) around the male pipe threads (MPT) on the stainless steel fitting o
7Order filter by calling Watts at 1-800-224-1299Item Needed: EDP# 7100109Includes: • (1) Carbon Block FilterThis reverse osmosis system contains a rep
8 Membrane Replacement This reverse osmosis system contains a replaceable component (the RO membrane) which is critical to the efficiency of the system
9iteM # edp # description1 7300052 MODULE2 7300034 ELBOW - 1/4" QC X 1/4" STEM (NOT SHOWN)3 7300025 FLOW RESTRICTOR (NOT SHOWN)4 7300000 TR